1.
Doc Ophthalmol ; 146(3): 199-210, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37269394

RESUMO

This document developed by the International Society for Clinical Electrophysiology of Vision (ISCEV) provides guidance for calibration and verification of stimulus and recording systems specific to clinical electrophysiology of vision. This guideline provides additional information for those using ISCEV Standards and Extended protocols and supersedes earlier Guidelines. The ISCEV guidelines for calibration and verification of stimuli and recording instruments (2023 update) were approved by the ISCEV Board of Directors 01, March 2023.


Assuntos
Eletrorretinografia , Visão Ocular , Eletrorretinografia/métodos , Calibragem
2.
Doc Ophthalmol ; 146(1): 1-2, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36637601
3.
Clin Exp Optom ; 106(8): 883-889, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36403264

RESUMO

CLINICAL RELEVANCE: Visual acuity measurement is important for the detection and monitoring of eye disorders. Developing accurate and sensitive visual acuity tests suitable for young children is therefore desirable. BACKGROUND: Recognition or form visual acuity (VA), which is measured with matching in children aged 3 years and up, is more sensitive for detecting visual deficits compared to resolution VA. The Waterloo Differential Acuity Test (WatDAT) is a proposed recognition VA test using the concept of identifying the "odd one out" among distractors. The WatDAT is expected to be cognitively easier than matching tests and therefore may be used in younger children. The purpose of this study is to investigate the testability of the WatDAT paradigm in children aged 12-36 months, and to determine the optimum format and number of distractors. METHODS: Fifty-one typically-developing children aged 12-36 months participated in the study. Data for Patti Pics (PP) and Face targets (FT) were collected for formats with 3, 4 and 5 distractors. The targets were presented binocularly on a computer touch screen at 30 cm. The task was to touch the face among identical non-faces or a house among circles. Following initial training, there were 5 presentations for each distractor format. Testability was defined as correctly identifying at least 4/5 presentations and was also determined for uncrowded PP symbols using matching. RESULTS: Of participants aged 18-36 months, 87% could perform the WatDAT PP targets with 3 distractors compared to 68% for the FT, while 48% could perform matching with PP. The testability for FT increased to 85% for children ≥22 months. Younger children showed lower testability. For the 3 distractor format, PP targets gave 9% testability in children 12 to <18 months, and FT gave a testability of 16% in children 12 to <22 months. CONCLUSION: WatDAT testability is higher than matching VA tests. This indicates that the newly developed WatDAT has potential for measuring recognition VA in children 18 months and older.


Assuntos
Testes Visuais , Humanos , Criança , Pré-Escolar , Acuidade Visual
4.
Ophthalmol Sci ; 3(1): 100243, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36545261

RESUMO

Purpose: To determine the characteristics and cause of the increase in the amplitude of flicker electroretinography (ERG) after cataract surgery. Design: Prospective, observational clinical study. Participants: Thirty patients who underwent cataract surgery. Methods: Flicker ERGs were recorded with the RETeval system without mydriasis. The central macular thickness (CMT) was measured by OCT and the aqueous flare value (AFV) by laser flare-cell photometry. These examinations were performed before surgery and 1 day, 1 week, 1 month, 2 months, and 3 months after surgery. Linear regression analysis through the origin was used to compare the correlations between the relative changes in flicker ERG amplitudes and the changes in the CMT and AFV at different times after the surgery. Main Outcome Measures: The amplitude of flicker ERGs, CMT, and AFV. Results: The mean amplitude of flicker ERGs increased significantly by 31% at 1 week after surgery (P < 0.001); a significant increase in the amplitudes was not present at 3 months after the surgery. The mean AFV was significantly increased at 1 day after surgery (P < 0.001), and the CMT was significantly increased at 1 to 3 months after surgery (P < 0.001). The changes in flicker ERG amplitudes at 1 week after surgery were significantly associated with the changes in the CMT at 1 to 3 months after surgery (P < 0.05), and they were weakly associated with the changes in AFV at 1 day after surgery (P = 0.05). Conclusions: These results suggest that the increase in the amplitude of flicker ERGs after cataract surgery is a transient phenomenon that has a peak at 1 week after surgery. The increase of flicker ERG amplitude was associated with measures that are frequently used to evaluate postoperative inflammation. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

5.
Doc Ophthalmol ; 145(3): 175-184, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36199003

RESUMO

PURPOSE: To develop and validate a flicker electroretinogram (ERG) protocol in term-born neonates as a potential tool for assessing preterm infants at risk of developing retinopathy of prematurity. METHODS: A custom flicker ERG protocol was developed for use with the hand-held RETeval® electrophysiology device. Feasibility of measuring flicker ERG through closed eyelids and without mydriasis was established in a pilot study enabling optimisation of the test protocol. Following this, healthy term-born neonates (gestational age 37-42 weeks) were recruited at the Neonatology clinic of the University Hospital Zurich. Flicker ERG recordings were performed using proprietary disposable skin electrodes during the first four days of life when the infants were sleeping. Flicker stimuli were presented at 28.3 Hz for a stimulus series at 3, 6, 12, 30, and 50 cd·s/m2, with two measurements at each stimulus level. Results were analysed offline. Flicker ERG peak times and amplitudes were derived from the averaged measurements per stimulus level for each subject. RESULTS: 28 term-born neonates were included in the analysis. All infants tolerated the testing procedure well. Flicker ERG recording was achieved in all subjects with reproducible flicker ERG waveforms for 30 and 50 cd·s/m2 stimuli. Reproducible ERGs were recorded in the majority of infants for the weaker stimuli (with detectable ERGs in 20/28, 25/28, and 27/28 at 3, 6, and 12 cd·s/m2, respectively). Flicker ERG amplitudes increased with increasing stimulus strength, with peak times concurrently decreasing slightly. CONCLUSION: Flicker ERG recording is feasible and reliably recorded in sleeping neonates through closed eyelids using skin electrodes and without mydriasis. Flicker ERG amplitude decreases for lower luminance flicker but remains detectable for 3 cd·s/m2 flicker in the majority of healthy term-born neonates. These data provide a basis to study retinal function in premature infants using this protocol.


Assuntos
Eletrorretinografia , Midríase , Recém-Nascido , Lactente , Humanos , Eletrorretinografia/métodos , Projetos Piloto , Estimulação Luminosa/métodos , Recém-Nascido Prematuro , Retina
6.
Doc Ophthalmol ; 144(3): 165-177, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35511377

RESUMO

The full-field electroretinogram (ERG) is a mass electrophysiological response to diffuse flashes of light and is used widely to assess generalized retinal function. This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for clinical ERG testing. Minimum protocols for basic ERG stimuli, recording methods and reporting are specified, to promote consistency of methods for diagnosis, monitoring and inter-laboratory comparisons, while also responding to evolving clinical practices and technology. The main changes in this updated ISCEV Standard for clinical ERGs include specifying that ERGs may meet the Standard without mydriasis, providing stimuli adequately compensate for non-dilated pupils. There is more detail about analysis of dark-adapted oscillatory potentials (OPs) and the document format has been updated and supplementary content reduced. There is a more detailed review of the origins of the major ERG components. Several tests previously tabulated as additional ERG protocols are now cited as published ISCEV extended protocols. A non-standard abbreviated ERG protocol is described, for use when patient age, compliance or other circumstances preclude ISCEV Standard ERG testing.


Assuntos
Eletrorretinografia , Sociedades Médicas , Eletrorretinografia/métodos , Humanos , Estimulação Luminosa/métodos , Retina , Visão Ocular
7.
Doc Ophthalmol ; 144(3): 163-164, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35594007
8.
Doc Ophthalmol ; 143(2): 141-153, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33778913

RESUMO

PURPOSE: Sedation with chloral hydrate or anesthesia using propofol allow ocular examination and testing in young children, but these drugs may affect electrophysiologic recordings. We compared the flash and pattern ERGs and VEPs recorded with each drug in a cohort of young children enrolled in a prospective study of optic nerve hypoplasia (ONH) syndrome. METHODS: ERGs and VEPs to light-adapted, standard, full-field flashes, to standard and steady-state pattern-reversal (PR) were recorded with cycloplegia in 9 participants. Age range at the first session, with chloral hydrate was 8-23 mo; at the second session with propofol it was 20-29 mo. Examiners masked to the drug and clinical conditions measured the waveforms for longitudinal, paired comparisons between the sessions. RESULTS: Flash ERG amplitudes did not differ between sessions; peak times were longer at the second session (propofol) by clinically insignificant amounts (< 2 ms, p = 0.002). Standard PERGs had larger amplitudes and later peaks in the second session (propofol) than with chloral hydrate (P50 2.9 vs 4.7 µV, p = 0.016 and 43 vs 52 ms, p < 0.001; N95 4.0 vs 6.1 µV, p = 0.003 and 91 vs 98.5 ms p = 0.034.). These differences were present for those with an interval of  > 10 mo between sessions (n = 5, 10 eyes) but not for those with a shorter inter-test interval (< 8 mo, p > 0.05, n = 4). Magnitudes of the steady-state PERGs did not differ between tests but the waveforms had earlier peaks at the second test with propofol. Flash VEP waveforms were present in 10/18 eyes and showed 72% agreement for recordability between sessions. Standard pattern VEPs were recordable in only a few eyes in this cohort with ONH. CONCLUSIONS: Light-adapted flash ERG waveforms were generally similar with chloral hydrate and with propofol. Larger PERGs with later peaks, found in the second session (propofol) could reflect maturation of the PERG generators, as the differences found were associated with a greater age difference between the sessions, but we do not rule out that small differences in the waveforms may be drug-related. There are insufficient VEP data from these children with ONH to identify drug-related or maturational effects on VEPs.


Assuntos
Anestesia , Eletrorretinografia , Propofol , Criança , Pré-Escolar , Hidrato de Cloral , Humanos , Estudos Prospectivos
9.
Doc Ophthalmol ; 142(1): 17-24, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32676804

RESUMO

The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for visual evoked potentials (VEPs) describes a minimum procedure for clinical VEP testing and encourages more extensive testing. This ISCEV extended protocol is an extension to the VEP standard. It describes procedures for recording multiple VEPs to a range of sizes of pattern stimuli to establish the VEP spatial frequency limit (threshold) and for relating this limit to visual acuity.


Assuntos
Eletrorretinografia , Potenciais Evocados Visuais , Sociedades Médicas , Visão Ocular , Acuidade Visual
10.
Eur J Neurosci ; 53(4): 1008-1018, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32935421

RESUMO

Rapid visual stimulation can increase synaptic efficacy by repeated synaptic activation. This long-term potentiation-like (LTP-like) effect can induce increased excitability in the human visual cortex. To examine the effect of rapid visual stimulation on perception, we tested the hypothesis that rapid monocular visual stimulation would increase the dominance of the stimulated eye in a binocular rivalry task. Participants (n = 25) viewed orthogonal 0.5 cpd gratings presented in a dichoptic anaglyph to induce binocular rivalry. Rivalry dynamics (alternation rate, dominance, and piecemeal durations) were recorded before and after 2 min of rapid monocular stimulation (9 Hz flicker of one grating) or a binocular control condition (9 Hz alternation of the orthogonal gratings viewed binocularly). Rapid monocular stimulation did not affect alternation rates or piecemeal percept duration. Unexpectedly, the rivalry dominance of the stimulated eye was significantly reduced. A further experiment revealed that this effect could not be explained by monocular adaptation. Together, the results suggest that rapid monocular stimulation boosts dominance in the non-stimulated eye, possibly by activating homeostatic interocular gain control mechanisms.


Assuntos
Disparidade Visual , Córtex Visual , Humanos , Estimulação Luminosa , Visão Binocular , Percepção Visual
11.
Doc Ophthalmol ; 142(1): 25-74, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32488810

RESUMO

PURPOSE: Visual evoked potentials (VEPs) can be used to measure visual resolution via a spatial frequency (SF) limit as an objective estimate of visual acuity. The aim of this systematic review is to collate descriptions of the VEP SF limit in humans, healthy and disordered, and to assess how accurately and precisely VEP SF limits reflect visual acuity. METHODS: The protocol methodology followed the PRISMA statement. Multiple databases were searched using "VEP" and "acuity" and associated terms, plus hand search: titles, abstracts or full text were reviewed for eligibility. Data extracted included VEP SF limits, stimulus protocols, VEP recording and analysis techniques and correspondence with behavioural acuity for normally sighted healthy adults, typically developing infants and children, healthy adults with artificially degraded vision and patients with ophthalmic or neurological conditions. RESULTS: A total of 155 studies are included. Commonly used stimulus, recording and analysis techniques are summarised. Average healthy adult VEP SF limits vary from 15 to 40 cpd, depend on stimulus, recording and analysis techniques and are often, but not always, poorer than behavioural acuity measured either psychophysically with an identical stimulus or with a clinical acuity test. The difference between VEP SF limit and behavioural acuity is variable and strongly dependent on the VEP stimulus and choice of acuity test. VEP SF limits mature rapidly, from 1.5 to 9 cpd by the end of the first month of life to 12-20 cpd by 8-12 months, with slower improvement to 20-40 cpd by 3-5 years. VEP SF limits are much better than behavioural thresholds in the youngest, typically developing infants. This difference lessens with age and reaches equivalence between 1 and 2 years; from around 3-5 years, behavioural acuity is better than the VEP SF limit, as for adults. Healthy, artificially blurred adults had slightly better behavioural acuity than VEP SF limits across a wide range of acuities, while adults with heterogeneous ophthalmic or neurological pathologies causing reduced acuity showed a much wider and less consistent relationship. For refractive error, ocular media opacity or pathology primarily affecting the retina, VEP SF limits and behavioural acuity had a fairly consistent relationship across a wide range of acuity. This relationship was much less consistent or close for primarily macular, optic nerve or neurological conditions such as amblyopia. VEP SF limits were almost always normal in patients with non-organic visual acuity loss. CONCLUSIONS: The VEP SF limit has great utility as an objective acuity estimator, especially in pre-verbal children or patients of any age with motor or learning impairments which prevent reliable measurement of behavioural acuity. Its diagnostic power depends heavily on adequate, age-stratified, reference data, age-stratified empirical calibration with behavioural acuity, and interpretation in the light of other electrophysiological and clinical findings. Future developments could encompass faster, more objective and robust techniques such as real-time, adaptive control. REGISTRATION: International prospective register of systematic reviews PROSPERO ( https://www.crd.york.ac.uk/PROSPERO/ ), registration number CRD42018085666.


Assuntos
Ambliopia , Potenciais Evocados Visuais , Adulto , Criança , Pré-Escolar , Eletrorretinografia , Humanos , Lactente , Visão Ocular , Acuidade Visual
12.
Front Neurosci ; 13: 607, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31249506

RESUMO

Recent evidence indicates that inhibition within the visual cortex is greater in older than young adults. Increased inhibition has been associated with reduced visual cortex plasticity in animal models. We investigated whether age-related increases in human visual cortex inhibition occur in conjunction with reduced visual cortex plasticity. Visual cortex inhibition was measured psychophysically using binocular rivalry alternation rates (AR) for dichoptic gratings. Slower ARs are associated with a greater concentration of the inhibitory neurotransmitter GABA within the human visual cortex. Visual cortex plasticity was measured using an established paradigm for induction of long-term potentiation (LTP) -like increases in visually evoked potential (VEP) amplitude. Following rapid visual stimulation, greater increases in VEP amplitude indicate greater visual cortex plasticity. The study involved two groups; young (18-40 years, n = 29) and older adults (60-80 years, n = 18). VEPs were recorded for a 1 Hz onset/offset checkerboard stimulus before and after 9 Hz visual stimulation with the same stimulus. ARs were slower in older than young adults. In contrast to most previous studies, VEP amplitudes were significantly reduced following the rapid visual stimulation for young adults; older adult VEP amplitudes were unaffected. Our AR results replicate previous observations of increased visual cortex inhibition in the older adults. Rapid visual stimulation significantly altered VEP amplitude in young adults, albeit in the opposite direction than predicted. VEP amplitudes did not change in older adults suggesting an association between increased inhibition and reduced plasticity within the human visual cortex.

13.
Doc Ophthalmol ; 138(3): 205-215, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30929108

RESUMO

The International Society for Clinical Electrophysiology of Vision (ISCEV) standard for full-field electroretinography (ERG) describes a minimum protocol for clinical testing but encourages additional ERG testing when appropriate. This ISCEV extended protocol describes methods to record and evaluate a light-adapted (LA) ERG stimulus-response series with increasing flash strengths. The LA ERG stimulus-response series (also referred to as the luminance-response or intensity-response series in the published literature) can characterise generalised cone system function more comprehensively than the ISCEV standard LA ERGs alone. The amplitude of LA ERG a-waves, arising from cones and cone off-bipolar cells, typically shows a saturating function. The LA ERG b-wave amplitudes, which arise primarily from activity of retinal bipolar cells, show an amplitude peak followed by a nonzero plateau (the "photopic hill" phenomenon). This ISCEV extended protocol specifies a stimulus-response series suitable to evaluate generalised dysfunction affecting the LA retina, to aid in distinguishing between the on- and off-responses of the cone system and to monitor ERG changes in these characteristics. The LA ERG stimulus-response series for a- and b-waves is recorded to a sequence of nine flash stimuli ranging from 0.03 to 300 cd s m-2, superimposed on a standard background of 30 cd m-2. A shorter protocol is also presented to measure the mid-range of the function (the "photopic hill") using 5 flash stimuli.


Assuntos
Protocolos Clínicos/normas , Eletrorretinografia/métodos , Oftalmopatias Hereditárias/fisiopatologia , Doenças Genéticas Ligadas ao Cromossomo X/fisiopatologia , Luz , Miopia/fisiopatologia , Cegueira Noturna/fisiopatologia , Estimulação Luminosa/métodos , Retina/fisiopatologia , Adulto , Humanos , Oftalmologia/organização & administração , Células Fotorreceptoras Retinianas Cones/fisiologia , Sociedades Médicas/organização & administração
14.
Invest Ophthalmol Vis Sci ; 58(12): 5280-5286, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29049731

RESUMO

Purpose: A small, full-field flicker electroretinogram (ERG) recording system was recently developed to record flicker ERGs without mydriasis (RETeval). The device delivers a stimulus with constant retinal illuminance by adjusting the retinal luminance to compensate for changes in the pupillary area. The purpose of this study was to determine what factors affect the fundamental components of the flicker ERGs recorded by RETeval in young healthy subjects. Methods: Flicker ERGs were recorded with the RETeval system from 150 eyes of 150 young healthy subjects (age, 20-29 years). Univariate and multivariate linear regression analyses were performed to identify the factors that affected the implicit times and amplitudes of the fundamental component of the flicker ERGs. The independent variables included age, sex, refractive error, axial length, and pupillary area. Results: Multivariate regression analyses indicated that a longer axial length (P = 0.03) and larger pupillary area (P = 0.008) were independent factors that were significantly associated with longer implicit times of the fundamental component of the flicker ERGs. Multivariate regression analyses also showed that the female sex (P = 0.03) was an independent factor, which was significantly associated with larger amplitude fundamental component of the flicker ERGs. Conclusions: These results indicate that the fundamental components of the RETeval flicker ERGs are significantly affected by the axial length, pupillary area, and sex of young healthy subjects. The results also suggest that it would be better to compensate for the Stiles-Crawford effect when flicker ERGs are recorded with natural pupils.


Assuntos
Pupila/fisiologia , Retina/fisiologia , Adulto , Comprimento Axial do Olho/anatomia & histologia , Eletrorretinografia , Feminino , Voluntários Saudáveis , Humanos , Iluminação , Masculino , Estimulação Luminosa/métodos , Estudos Prospectivos , Retina/efeitos da radiação , Células Fotorreceptoras Retinianas Cones , Fatores Sexuais , Adulto Jovem
15.
Doc Ophthalmol ; 135(2): 121-132, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28638951

RESUMO

PURPOSE: Amplitudes of electroretinograms (ERG) are enhanced during acute, moderate elevation of intraocular pressure (IOP) in rats anaesthetised with isoflurane. As anaesthetics alone are known to affect ERG amplitudes, the present study compares the effects of inhalant isoflurane and injected ketamine:xylazine on the scotopic threshold response (STR) in rats with moderate IOP elevation. METHODS: Isoflurane-anaesthetised (n = 9) and ketamine:xylazine-anaesthetised (n = 6) rats underwent acute unilateral IOP elevation using a vascular loop anterior to the equator of the right eye. STRs to a luminance series (subthreshold to -3.04 log scotopic cd s/m2) were recorded from each eye of Sprague-Dawley rats before, during, and after IOP elevation. RESULTS: Positive STR (pSTR) amplitudes for all conditions were significantly smaller (p = 0.0001) for isoflurane- than for ketamine:xylazine-anaesthetised rats. In addition, ketamine:xylazine was associated with a progressive increase in pSTR amplitudes over time (p = 0.0028). IOP elevation was associated with an increase in pSTR amplitude (both anaesthetics p < 0.0001). The absolute interocular differences in IOP-associated enhancement of pSTR amplitudes for ketamine:xylazine and isoflurane were similar (66.3 ± 35.5 vs. 54.2 ± 24.1 µV, respectively). However, the fold increase in amplitude during IOP elevation was significantly higher in the isoflurane- than in the ketamine:xylazine-anaesthetised rats (16.8 ± 29.7x vs. 2.1 ± 2.7x, respectively, p = 0.0004). CONCLUSIONS: The anaesthetics differentially affect the STRs in the rat model with markedly reduced amplitudes with isoflurane compared to ketamine:xylazine. However, the IOP-associated enhancement is of similar absolute magnitude for the two anaesthetics, suggesting that IOP stress and anaesthetic effects operate on separate retinal mechanisms.


Assuntos
Anestésicos Combinados/farmacologia , Anestésicos Inalatórios/farmacologia , Pressão Intraocular/efeitos dos fármacos , Isoflurano/farmacologia , Ketamina/farmacologia , Visão Noturna/fisiologia , Xilazina/farmacologia , Animais , Adaptação à Escuridão , Eletrorretinografia , Injeções Intraperitoneais , Masculino , Ratos , Ratos Sprague-Dawley , Retina/fisiologia , Limiar Sensorial/fisiologia
16.
Doc Ophthalmol ; 133(1): 1-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27443562

RESUMO

Visual evoked potentials (VEPs) can provide important diagnostic information regarding the functional integrity of the visual system. This document updates the ISCEV standard for clinical VEP testing and supersedes the 2009 standard. The main changes in this revision are the acknowledgment that pattern stimuli can be produced using a variety of technologies with an emphasis on the need for manufacturers to ensure that there is no luminance change during pattern reversal or pattern onset/offset. The document is also edited to bring the VEP standard into closer harmony with other ISCEV standards. The ISCEV standard VEP is based on a subset of stimulus and recording conditions that provide core clinical information and can be performed by most clinical electrophysiology laboratories throughout the world. These are: (1) Pattern-reversal VEPs elicited by checkerboard stimuli with large 1 degree (°) and small 0.25° checks. (2) Pattern onset/offset VEPs elicited by checkerboard stimuli with large 1° and small 0.25° checks. (3) Flash VEPs elicited by a flash (brief luminance increment) which subtends a visual field of at least 20°. The ISCEV standard VEP protocols are defined for a single recording channel with a midline occipital active electrode. These protocols are intended for assessment of the eye and/or optic nerves anterior to the optic chiasm. Extended, multi-channel protocols are required to evaluate postchiasmal lesions.


Assuntos
Eletrofisiologia/normas , Potenciais Evocados Visuais , Visão Ocular/fisiologia , Humanos , Nervo Óptico/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Sociedades Médicas , Córtex Visual/fisiologia , Campos Visuais/fisiologia
18.
Doc Ophthalmol ; 131(1): 25-34, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25761929

RESUMO

PURPOSE: Pattern electroretinograms (PERGs) have inherently low signal-to-noise ratios and can be difficult to detect when degraded by pathology or noise. We compare an objective system for automated PERG analysis with expert human interpretation in children with optic nerve hypoplasia (ONH) with PERGs ranging from clear to undetectable. METHODS: PERGs were recorded uniocularly with chloral hydrate sedation in children with ONH (aged 3.5-35 months). Stimuli were reversing checks of four sizes focused using an optical system incorporating the cycloplegic refraction. Forty PERG records were analysed; 20 selected at random and 20 from eyes with good vision (fellow eyes or eyes with mild ONH) from over 300 records. Two experts identified P50 and N95 of the PERGs after manually deleting trials with movement artefact, slow-wave EEG (4-8 Hz) or other noise from raw data for 150 check reversals. The automated system first identified present/not-present responses using a magnitude-squared coherence criterion and then, for responses confirmed as present, estimated the P50 and N95 cardinal positions as the turning points in local third-order polynomials fitted in the -3 dB bandwidth [0.25 … 45] Hz. Confidence limits were estimated from bootstrap re-sampling with replacement. The automated system uses an interactive Internet-available webpage tool (see http://clinengnhs.liv.ac.uk/esp_perg_1.htm). RESULTS: The automated system detected 28 PERG signals above the noise level (p ≤ 0.05 for H0). Good subjective quality ratings were indicative of significant PERGs; however, poor subjective quality did not necessarily predict non-significant signals. P50 and N95 implicit times showed good agreement between the two experts and between experts and the automated system. For the N95 amplitude measured to P50, the experts differed by an average of 13% consistent with differing interpretations of peaks within noise, while the automated amplitude measure was highly correlated with the expert measures but was proportionally larger. Trial-by-trial review of these data required approximately 6.5 h for each human expert, while automated data processing required <4 min, excluding overheads relating to data transfer. CONCLUSIONS: An automated computer system for PERG analysis, using a panel of signal processing and statistical techniques, provides objective present/not-present detection and cursor positioning with explicit confidence intervals. The system achieves, within an efficient and robust statistical framework, estimates of P50 and N95 amplitudes and implicit times similar to those of clinical experts.


Assuntos
Eletrorretinografia/métodos , Prova Pericial , Doenças do Nervo Óptico/congênito , Retina/fisiopatologia , Células Ganglionares da Retina/fisiologia , Processamento de Sinais Assistido por Computador , Pré-Escolar , Interpretação Estatística de Dados , Potenciais Evocados Visuais/fisiologia , Feminino , Humanos , Lactente , Masculino , Doenças do Nervo Óptico/fisiopatologia , Estimulação Luminosa , Estudos Prospectivos , Razão Sinal-Ruído
19.
Doc Ophthalmol ; 130(1): 1-12, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25502644

RESUMO

This document, from the International Society for Clinical Electrophysiology of Vision (ISCEV), presents an updated and revised ISCEV Standard for full-field clinical electroretinography (ffERG or simply ERG). The parameters for Standard flash stimuli have been revised to accommodate a variety of light sources including gas discharge lamps and light emitting diodes. This ISCEV Standard for clinical ERGs specifies six responses based on the adaptation state of the eye and the flash strength: (1) Dark-adapted 0.01 ERG (rod ERG); (2) Dark-adapted 3 ERG (combined rod-cone standard flash ERG); (3) Dark-adapted 3 oscillatory potentials; (4) Dark-adapted 10 ERG (strong flash ERG); (5) Light-adapted 3 ERG (standard flash "cone" ERG); and (6) Light-adapted 30 Hz flicker ERG. ISCEV encourages the use of additional ERG protocols for testing beyond this minimum standard for clinical ERGs.


Assuntos
Eletrorretinografia/normas , Oftalmologia/organização & administração , Células Fotorreceptoras de Vertebrados/fisiologia , Sociedades Médicas/normas , Acomodação Ocular/fisiologia , Adaptação à Escuridão/fisiologia , Eletrodos , Eletrorretinografia/instrumentação , Humanos , Estimulação Luminosa/métodos , Neurônios Retinianos/fisiologia
20.
Adv Exp Med Biol ; 801: 477-85, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24664734

RESUMO

Retinitis Pigmentosa (RP) is a genetically heterogeneous disorder characterized by rod and cone photoreceptor cell dysfunction. X-linked RP (XLRP) is one of the most severe forms of human retinal degeneration, as determined by age-of-set and progression, and accounts for six to 20 % of all RP cases. At least six XLRP loci have been identified, but RP3 is the major subtype of XLRP, accounting for 70 to 80 % of affected families. The RPGR gene is responsible for the RP3 form of XLRP and is mutated in 10-20 % of all RP patients. The pathogenesis of retinitis pigmentosa GTPase regulator (RPGR) mutant-causing RP is not clear, different animal models have been used to understand the pathogenesis of these diseases. In this brief review, we will summarize the functional characterization of RPGR and highlight recent studies in animal models, which will not only shed light on the disease mechanisms in XLRP but will also provide therapeutic strategies for RP treatment.


Assuntos
Modelos Animais de Doenças , Proteínas do Olho/genética , Proteínas do Olho/fisiologia , Retinose Pigmentar , Sequência de Aminoácidos , Animais , Cães , Genes Ligados ao Cromossomo X/genética , Humanos , Camundongos , Dados de Sequência Molecular , Retinose Pigmentar/etiologia , Retinose Pigmentar/genética , Retinose Pigmentar/patologia , Peixe-Zebra
SELEÇÃO DE REFERÊNCIAS